Diesel Engines,Generating Sets,Generator,Pump Sets,Alternators,Gas Engines,Invertors,Engine,Genset,Canopy,Sheet Metal Components,Components,Metal Components, diesel Engines,Generating Sets,Generator,Pump Sets,Alternators,Gas Engines,Invertors,Engine,Genset,Canopy,Sheet Metal Components,Components,Metal Components

<< Back to Home

 Contact Us | About Us                

 
 

 


Aakar Group of Industries

Aakar Sheet Metal - A Sister Venture of Aakar Group Of Industries Aakar Casting - Another Sister Venture of Aakar Group Of Industries

Diesel Engines | Generating Sets | Pump Sets | Alternators | Gas Engines | Invertors | Renewal Energy | Acoustic Enclosure (Canopy)      
 

Alternators             

 

 

 


Single Phase :: Three Phase

Semi Brushless Alternator
 

 

Brushless Alternator

 

Single Phase

   

2.2 to 16 KVA

:: 10 to 45 KVA :: Welding Alternator ::   Top

 

A. C. GENERATOR
Voltage
230 V
Phase
Single
Frequency
50/60 Hz
Regulation
± 5 % Max.
Insulation
F Class
Mounting
Foot
RPM
1500/1800
CENTER HEIGHT
2.2 KVA
140 MM
3.5 TO 10 kW
150 MM

12 TO 16 kW

200 MM


Technical
Specification

Alternator Model
Rated Output
No. of Phase
Current (AMPS)
Power Factor

Recommended Engine Power  (BHP)

Nett Weight (KG)

kVA
kW
APAS   2.2
2.2
2.2
ONE
9.5
1.0 (UPF)
3.5
 
APAS   3.5
3.5
3.5
ONE
15.2
1.0 (UPF)
6.5
69
APAS  5.0
5.0
5.0
ONE
21.7
1.0 (UPF)
8.0
75
APAS   6.0
6.0
6.0
ONE
26.1
1.0 (UPF)
10.0
78
APAS   7.5
7.5
7.5
ONE
32.6
1.0 (UPF)
12.0
84
APAS   8.5
8.5
8.5
ONE
37.0
1.0 (UPF)
14.0
92
APAS   10.0
10.0
10.0
ONE
43.5
1.0 (UPF)
16.0
95
APAS   12.0
12.0
12.0
ONE
52.2
1.0 (UPF)
20.0
 
APAS   14.0
14.0
14.0
ONE
60.9
1.0 (UPF)
23.0
 
APAS   16.00
16.0
16.0
ONE
69.6
1.0 (UPF)
25.0
 

 

10 to 45 KVA
 

:: 2.2 to 16 KVA :: Welding Alternator ::    Top
 

A. C. GENERATOR
Voltage
230 V
Phase
Single
Frequency
50/60 Hz
Regulation
± 5 % Max.
Insulation
F Class
Mounting
Foot
RPM 1500/1800

CENTER HEIGHT

5 TO 10 kVA

150 MM

12 TO 25 kVA

200 MM

30 TO 50 kVA

250 MM

62 to 82  kVA

280 MM


Technical
Specification

Alternator Model
AC Generators ( Alternator ) 
Recommended  Engine Rating
  (HP)

Nett. Weight (KG)

Rating
NO. of Phase
Current (AMPS)
Power Factor
KVA
KW
APAS 10 10 8 ONE 43.5
0.8 (LAG)
14 137
APAS 12.5 12.5 10 ONE 54.3
0.8 (LAG)
16 141
APAS 15 15 12 ONE 65.2
0.8 (LAG)
20 154
APAS 20 20 16 ONE 87
0.8 (LAG)
26 175
APAS 25 25 20 ONE 109
0.8 (LAG)
32 218
APAS 30 30 24 ONE 130
0.8 (LAG)
38 224
APAS 40 40 32 ONE 174
0.8 (LAG)
52 348
APAS 50 50 42 ONE 217
0.8 (LAG)
60 365

 

Welding Alternator


::
2.2 to 16 KVA :: 10 to 45 KVA ::    Top
 



 

WELDING GENERATOR
Type
Direct Welding
Without
Transformer
Welding Voltage
75/26 V
Frequency
50 Hz
Regulation
± 5 %
Insulation
F Class
Rev. Speed
1500 RPM


Technical
Specification

Model
APWA - 8
APWA - 6
WELDING ROD SIZE ( SWG. )
12 TO 8.0
12 TO 6.0
WELDING ROD SIZE ( mm )
2.5 TO 4.0
2.5 TO 5.0
WELDING CURRENT (AMPS)
Max. 220
Max. 400
CURRENT CONTROLLING
4 STEPS
4 STEPS
SINGLE PHASE LOAD AT 230 V
2.0 KW(8.7 Amp)
3.0 KW( 13 Amp)

RECOMMENDED ENGINE RATING

12.0 H.P. 20.0 H.P.
USER SECTORS

DOMESTIC, COMMERCIAL AND INDUSTRIAL

APPLICATION

DIRECT ONLINE WELDING

 

Three Phase

 

5 to 20 KVA
 

:: 10 to 82.5 KVA ::   Top

A. C. GENERATOR
Voltage
230/415 V
Phase
Three
Frequency
50/60 Hz
Regulation
± 5 % Max.
Insulation
F Class
Mounting
Foot
RPM
1500/1800
CENTER HEIGHT
2.2 KVA
140 MM
3.5 TO 10 kW
150 MM

12 TO 16 kW

200 MM


Technical
Specification

Alternator Model
Rated Output
No. of Phase
Current (AMPS)
Power Factor
Recommended Engine Power (BHP)

Nett Weight (KG)

kVA kW
APAT  5
5.0
4.0
THREE
7.0
0.8 (LAG)
6.5
76
APAT  6.25
6.25
5.0
THREE
8.7
0.8 (LAG)
8.0
82
APAT   7.5
7.5
6.0
THREE
10.4
0.8 (LAG)
10.0
85
APAT   8.7
8.7
7.5
THREE
12.2
0.8 (LAG)
12.0
90
APAT 10
10.0
8.5
THREE
13.9
0.8 (LAG)
14.0
100
APAT 12.5
12.5
10.0
THREE
17.4
0.8 (LAG)
16.0
104
APAT 15
15.0
12.0
THREE
20.8
0.8 (LAG)
20.0
 
APAT  17.5
17.5
14.0
THREE
24.3
0.8 (LAG)
23.0
 
APAT  20
20.0
16.0
THREE
27.8
0.8 (LAG)
25.0
 

 

10 to 82.5 KVA

:: 5 to 20 KVA ::   Top

 

A. C. GENERATOR
Voltage
230/415 V
Phase
Three
Frequency
50/60 Hz
Regulation
± 5 % Max.
Insulation
F Class
Mounting
Foot
RPM 1500/1800

CENTER HEIGHT

5 TO 10 kVA

150 MM

12 TO 25 kVA

200 MM

30 TO 50 kVA

250 MM

62 to 82  kVA

280 MM


Technical
Specification

Alternator Model
AC Generators ( Alternator ) 
Recommended  Engine Rating
  (HP)

Nett. Weight (KG)

Rating
NO. of Phase
Current (AMPS)
Power Factor
KVA
KW
APAT 10
10
8
THREE
13.9
0.8 (LAG)
14
137
APAT 12.5
12.5
10
THREE
17.4
0.8 (LAG)
16
141
APAT 15
15
12
THREE
21
0.8 (LAG)
20
154
APAT 20
20 16
THREE
28
0.8 (LAG)
26 175
APAT 25
25 20
THREE
35
0.8 (LAG)
32 218
APAT 30
30 24
THREE
42
0.8 (LAG)
38 224
APAT 40
40 32
THREE
55.6
0.8 (LAG)
52 348
APAT 50
50 40
THREE
69.5
0.8 (LAG)
64 365
APAT 62.5
62.5 50
THREE
87
0.8 (LAG)
80 500
APAT 82.5 82.5 66
THREE
115
0.8 (LAG)
105 550

 

Diesel Engines | Generating Sets | Pump Sets | Alternators | Gas Engines | Invertors | Renewal Energy | Acoustic Enclosure (Canopy)

 

Contact Us | About Us  | Home

All Rights Reserved Aakar Group of Industries

Diesel Engines,Generating Sets,Generator,Pump Sets,Alternators,Gas Engines,Invertors,Engine,Genset,Canopy,Sheet Metal Components,Components,Metal Components, diesel Engines,Generating Sets,Generator,Pump Sets,Alternators,Gas Engines,Invertors,Engine,Genset,Canopy,Sheet Metal Components,Components,Metal Components